Dynamic Fixation Versus Trans-Syndesmotic Screw Fixation in Ankle Fractures With Syndesmotic Injury: Functional Outcomes, Complications, and Need for Reintervention

Autores/as

DOI:

https://doi.org/10.64784/356

Palabras clave:

ankle fracture, syndesmotic injury, dynamic fixation, suture-button, syndesmotic screw, trans-syndesmotic fixation, functional outcomes, complications, implant failure, malreduction, hardware removal, reoperation

Resumen

Syndesmotic injury associated with ankle fractures represents a relevant challenge in orthopaedic trauma because inadequate stabilization may compromise ankle congruence, functional recovery, and long-term joint preservation. Trans-syndesmotic screw fixation has traditionally been used as the standard stabilization method; however, concerns related to implant rigidity, screw breakage, symptomatic hardware, and the need for secondary procedures have promoted increasing interest in dynamic suture-button fixation. This study comparatively evaluated both fixation strategies through a systematic review of clinical evidence, focusing on functional outcomes, syndesmotic reduction, postoperative complications, implant-related events, and reintervention. Randomized controlled trials, comparative studies, systematic reviews, meta-analyses, and long-term follow-up investigations were analyzed according to predefined eligibility criteria. Functional recovery was primarily assessed using the American Orthopaedic Foot & Ankle Society Ankle-Hindfoot Score and the Olerud-Molander Ankle Score. Dynamic fixation showed consistently favorable functional results, although the magnitude of the differences did not always exceed clinically meaningful thresholds. The most pronounced differences were identified in implant-related complications and secondary surgical procedures. Suture-button fixation was associated with substantially lower rates of implant breakage and hardware removal and with a reduced risk of unplanned reoperation. Earlier evidence also suggested lower syndesmotic malreduction with dynamic fixation, although more recent pooled analyses have not consistently confirmed a statistically significant difference in this outcome. Overall, dynamic fixation appears to provide functional outcomes that are at least equivalent to those achieved with trans-syndesmotic screws while offering a more favorable complication and reintervention profile. Nevertheless, both techniques remain effective when anatomical reduction is achieved, and fixation selection should consider fracture morphology, syndesmotic instability, patient characteristics, rehabilitation requirements, implant availability, and surgeon experience.

Referencias

• Altmeppen, J. N., Colcuc, C., Balser, C., Gramlich, Y., Klug, A., Neun, O., Manegold, S., Hoffmann, R., & Fischer, S. (2022). A 10-year follow-up of ankle syndesmotic injuries: Prospective comparison of knotless suture-button fixation and syndesmotic screw fixation. Journal of Clinical Medicine, 11(9), 2524.

• Andersen, M. R., Frihagen, F., Hellund, J. C., Madsen, J. E., & Figved, W. (2018). Randomized trial comparing suture button with single syndesmotic screw for syndesmosis injury. The Journal of Bone and Joint Surgery. American Volume, 100(1), 2–12.

• Cho, T., Waters, A., Senthilkumar, S., Shendge, S., & Liu, J. (2024). Comparison of the outcomes of syndesmotic ankle fractures treated with dynamic fixation versus static fixation versus fibular nail: A meta-analysis and systematic review. Annals of Joint, 9, 36.

• Elabd, A., Abdullah, S., Kandel, W., & Hegazy, M. (2021). Syndesmotic stabilization: Syndesmotic screw versus flexible fixation: A systematic review. The Journal of Foot & Ankle Surgery, 60(5), 998–1007.

• Gan, K., Zhou, K., Hu, K., Lu, L., Gu, S., & Shen, Y. (2019). Dynamic fixation versus static fixation for distal tibiofibular syndesmosis injuries: A meta-analysis. Medical Science Monitor, 25, 1314–1322.

• Gan, K., Xu, D., Hu, K., Wu, W., & Shen, Y. (2020). Dynamic fixation is superior in terms of clinical outcomes to static fixation in managing distal tibiofibular syndesmosis injury. Knee Surgery, Sports Traumatology, Arthroscopy, 28(1), 270–280.

• Inge, S. Y., Pull ter Gunne, A. F., Aarts, C. A. M., & Bemelman, M. (2016). A systematic review on dynamic versus static distal tibiofibular fixation. Injury, 47(12), 2627–2634.

• Kocadal, O., Yucel, M., Pepe, M., Aksahin, E., Aktekin, C. N., & Acar, B. (2016). Evaluation of reduction accuracy of suture-button and screw fixation techniques for syndesmotic injuries. Foot & Ankle International, 37(12), 1317–1325.

• Laflamme, M., Belzile, E. L., Bédard, L., van den Bekerom, M. P. J., Glazebrook, M., & Pelet, S. (2015). A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture. Journal of Orthopaedic Trauma, 29(5), 216–223.

• Lehtola, R., Leskelä, H.-V., Flinkkilä, T., Pakarinen, H., Niinimäki, J., Savola, O., Ohtonen, P., & Kortekangas, T. (2021). Suture button versus syndesmosis screw fixation in pronation-external rotation ankle fractures: A minimum 6-year follow-up of a randomised controlled trial. Injury, 52(10), 3143–3149.

• Nieuwenkamp, C. L., Tausendfreund, J., & Schepers, T. (2026). Suture button versus syndesmotic screw fixation in acute ankle fractures with syndesmotic injury: An umbrella review of functional outcomes and clinical relevance based on the minimal clinically important difference. Injury, 57(3), 113054.

• Ræder, B. W., Figved, W., Madsen, J. E., Frihagen, F., Jacobsen, S. B., & Andersen, M. R. (2020). Better outcome for suture button compared with single syndesmotic screw for syndesmosis injury: Five-year results of a randomized controlled trial. The Bone & Joint Journal, 102-B(2), 212–219.

• Ramadanov, N., Bueschges, S., & Dimitrov, D. (2021). Comparison of outcomes between suture button technique and screw fixation technique in patients with acute syndesmotic diastasis: A meta-analysis of randomized controlled trials. Foot & Ankle Orthopaedics, 6(4), 24730114211061405.

• Sanders, D., Schneider, P., Taylor, M., Tieszer, C., Lawendy, A. R., & Canadian Orthopaedic Trauma Society. (2019). Improved reduction of the tibiofibular syndesmosis with TightRope compared with screw fixation: Results of a randomized controlled study. Journal of Orthopaedic Trauma, 33(11), 531–537.

• Shimozono, Y., Hurley, E. T., Myerson, C. L., Murawski, C. D., & Kennedy, J. G. (2019). Suture button versus syndesmotic screw for syndesmosis injuries: A meta-analysis of randomized controlled trials. The American Journal of Sports Medicine, 47(11), 2764–2771.

• Thornes, B., Shannon, F., Guiney, A.-M., Hession, P., & Masterson, E. (2005). Suture-button syndesmosis fixation: Accelerated rehabilitation and improved outcomes. Clinical Orthopaedics and Related Research, 431, 207–212.

• Wang, Q., Liu, S., Wang, Z., Li, A., & Ding, J. (2024). Meta-analysis of elastic versus rigid fixation in the treatment of acute tibiofibular syndesmosis injury. Systematic Reviews, 13, 51.

• Xie, L., Xie, H., Wang, J., Chen, C., Zhang, C., Chen, H., & Zheng, W. (2018). Comparison of suture button fixation and syndesmotic screw fixation in the treatment of distal tibiofibular syndesmosis injury: A systematic review and meta-analysis. International Journal of Surgery, 60, 120–131.

• Xu, B., Wang, S., Tan, J., Chen, W., & Tang, K.-L. (2023). Comparison of suture button and syndesmotic screw for ankle syndesmotic injuries: A meta-analysis of randomized controlled trials. Orthopaedic Journal of Sports Medicine, 11(1), 23259671221127665.

• Zhang, P., Liang, Y., He, J., Fang, Y., Chen, P., & Wang, J. (2017). A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury. BMC Musculoskeletal Disorders, 18, 286.

Publicado

2026-10-07

Cómo citar

[1]
Andrés Ricardo Arévalo Sánchez, Tran., “Dynamic Fixation Versus Trans-Syndesmotic Screw Fixation in Ankle Fractures With Syndesmotic Injury: Functional Outcomes, Complications, and Need for Reintervention”, IECCMEXICO, vol. 5, no. 2, Oct. 2026, doi: 10.64784/356.